RYDBATT (Shenzhen RYDBATT Electronics Co., Ltd., est. 2005) builds 18650, 21700, and LiFePO4 OEM/ODM battery systems with in-house BMS, PACK engineering, automated assembly, and serial-level traceability. The record framework below is the same outgoing-QC discipline we apply before any batch leaves the factory.
 

1. Why "All Passed" Is Not Enough

A generic COA that says "100% tested, all qualified" cannot answer the only questions that matter during a warranty claim:

  • Which cell lot was used in this pack?
  • What were the incoming capacity and resistance values?
  • Was the weld process within the approved window?
  • Which BMS firmware version was programmed?
  • What were the actual EOL voltage, capacity, and protection results?
  • Who tested it, when, and on which line?

Procurement-grade records connect the result to the exact product, lot, and serial number.
 

2. The Record Map: From Cell to Carton

Stage Core Records Procurement Value
IQC Cell identity, lot, OCV, IR, capacity, self-discharge Confirms material matched the approved BOM
Cell matching Group ID, capacity/IR/OCV spread Predicts balance and cycle life
IPQC Weld params, pull test, polarity, insulation, torque Catches assembly and connection risk
BMS Firmware version, protection triggers, comms check Ensures behavior matches the validated baseline
Aging Formation, rest drift, temperature log Identifies weak cells before shipment
EOL Per-pack capacity, impedance, safety, function Proof the finished pack meets spec
OQC Label, serial, packaging, release sign-off Prevents mixed batches and wrong shipments


3. IQC Records: Incoming Cell Evidence

Require the incoming inspection report to include:

  • Cell manufacturer, model, chemistry, grade window
  • Lot code, production date, supplier batch document
  • Appearance check: no dent, leak, oxidation, or terminal damage
  • Open-circuit voltage under defined rest condition
  • AC-IR or DC-IR with declared method
  • Capacity grading at controlled C-rate and temperature
  • Self-discharge after storage window
  • Dimension and mass check vs approved drawing
  • Statistical spread: min / max / standard deviation, not only average
     
IQC record must show:
cell model + lot
OCV + IR + capacity
self-discharge grouping window
quarantine disposition
 


4. Cell-Matching Records

  • Grouping method: capacity, IR, OCV, SOC consistency
  • Accepted matching window for the project
  • Group ID linked to pack build record
  • No mixed production weeks inside one pack without approval

Even "Grade A" cells can age badly if the pack is built from an unbalanced group.


5. IPQC Records: Assembly and Connection Evidence

Weld and electrical connection

  • Spot-weld/laser-weld parameters: energy, pressure, time, electrode status
  • Pull/peel test sampling result and acceptance limit
  • Joint resistance where applicable
  • Polarity and busbar alignment check
  • Continuity of sensing and balancing wires

Mechanical and insulation

  • Torque records for terminals and fasteners
  • Insulation resistance before enclosure close
  • Foreign-object check inside enclosure
  • Harness routing, strain relief, connector orientation
  • Enclosure fit, gasket, label position


6. BMS Verification Records

  • BMS hardware revision and firmware/parameter-file version
  • Over-voltage / under-voltage protection and recovery
  • Charge/discharge over-current response
  • Short-circuit protection timing
  • Over/under-temperature cutoffs
  • Cell balancing behavior
  • SOC/SOH initialization check
  • Communication handshake where equipped
  • Per-pack firmware flash log

Two packs with the same BMS board can behave differently if the parameter file drifts. The record must capture the version, not just the part number.


7. Aging and Formation Records

  • Formation cycle count and charge/discharge profile
  • Rest period and voltage-drift observation
  • Temperature logging under load
  • Abnormal self-discharge or heating flags
  • Rework/retest actions and verification


8. EOL Records: Per-Pack Outgoing Test Data

Category Required EOL Record
Electrical OCV, pack impedance, discharge capacity (Ah/Wh), load curve
Safety Insulation resistance, dielectric/hipot, reverse-polarity safeguard
Function BMS protection trip/recovery, balancing, indicator, sleep/wake
Interface Connector continuity, communication frame, host handshake
Release Serial scan, label check, shipping-mode state, test pass/fail
EOL record must be: 100% per pack + tied to serial number + tied to BMS firmware + stored with test timestamp + retrievable for warranty/recall


9. OQC and Shipment Release Records

  • Pack serial ↔ cell lot ↔ BMS firmware traceability list
  • Visual and label verification against approved sample
  • Packing list, carton ID, pallet mapping
  • Shipping SOC and transport mode confirmation
  • Dangerous-goods marking and UN documentation check
  • Final release sign-off by QC owner
  • Nonconformance and rework history for the lot
     

10. Compliance and Certificate Package

  • Certificate of Conformance (COA/COC) for the exact SKU
  • UN38.3 test summary matched to configuration
  • MSDS/SDS current revision
  • CE / RoHS where applicable
  • IEC 62133-2 / UL path by market and project scope
  • Model, capacity, BMS, and cell configuration must match the certificate

A certificate for a similar pack does not cover a changed S/P ratio, cell model, or BMS revision.


11. The Minimum Document Package per Batch

Shipment document package:
1. Incoming cell inspection summary
2. Cell-matching / group record
3. IPQC weld & assembly log
4. BMS firmware & protection test record
5. Aging observation record
6. Per-pack EOL test data (CSV or structured report)
7. OQC release record
8. Serial-to-lot traceability list
9. Packing list + carton/pallet map
10. COA + UN38.3 + MSDS
11. Nonconformance & rework summary
12. Test-equipment calibration status


12. RFQ / Quality-Agreement Clause

Write into the PO or quality agreement:
- Outgoing records delivered before final payment
- Per-pack serial-linked EOL data
- Cell lot + BMS firmware traceability
- Defined AQL for incoming/outgoing inspection
- COA, UN38.3, MSDS for exact SKU
- Random serial audit on arrival - Record retention period (e.g., 3–5 years)
- Nonconformance escalation and recall procedure


13. Red Flags in Shipment Documentation

  • Only a one-page "all passed" COA
  • No serial numbers, only batch quantity
  • Cell lot not disclosed
  • BMS firmware version missing
  • EOL limits not defined, only pass/fail ticks
  • Certificate references a different model/capacity
  • Packing list and serial list do not match
  • No rework or nonconformance record


14. Why Procurement Teams Work With RYDBATT

  • 18650 / 21700 / LiFePO4 OEM/ODM since 2005
  • IQC grading: capacity, IR, OCV, self-discharge, lot ID
  • Cell matching, weld control, IPQC, first-article inspection
  • BMS functional test: protection, balancing, communication
  • Aging + 100% EOL electrical and safety test
  • Per-pack serial → cell-lot traceability
  • COA, UN38.3, MSDS, CE/RoHS documentation support
  • Outgoing record package delivered with each shipment
Request an Outgoing-QC Record Template →

 

FAQ

Q: What inspection records should accompany an 18650 pack shipment?

A: At minimum: incoming cell inspection (model, lot, OCV, IR, capacity, self-discharge), cell-matching record, IPQC weld/assembly log, BMS firmware and protection test, EOL electrical and safety test per pack, OQC release record, packing list, serial-to-lot traceability, COA, and UN38.3/MSDS matched to the exact SKU.

Q: Is a generic "all passed" certificate enough?

A: No. A one-page statement gives little protection. Records should be tied to pack serial numbers, lot codes, test conditions, acceptance limits, and responsible stations so a field issue can be traced back.

Q: Should every 18650 pack be tested before shipment?

A: Functional and safety checks should be 100% at end-of-line. Destructive weld/pull and environmental tests are usually sampled by an agreed plan, but the process must be controlled and recorded.

Q: What traceability must exist in the shipment documents?

A: Pack serial linked to cell lot, BMS firmware version, production date/line/shift, weld log, test data, nonconformance handling, and rework history.

Q: How does RYDBATT handle outgoing inspection records?

A: RYDBATT runs IQC, IPQC, BMS verification, aging, 100% EOL testing, and OQC release, then ships per-pack outgoing test records tied to serial number, plus COA and transport compliance documents.

Send Inquiry