12S 38.4V 200Ah LiFePO4 Module | CAN/RS485

12S 38.4V 200Ah LiFePO4 Module | CAN/RS485
Details:
RYDBATT 12S 38.4V 200Ah (7.68kWh) LiFePO4 smart-communication module — 100A cont./300A peak, IP67. OEM/ODM for material handling, off-grid and industrial equipment. UN38.3 supported.
Send Inquiry
Description
Send Inquiry

 

product-378-322

12S 38.4V 200Ah Smart-Communication LiFePO4 Power Module

OEM/ODM High-Capacity Module for Material Handling, Off-Grid & Industrial Equipment

The RYDBATT RYD-38200-IND is built on a 12S LiFePO4 architecture (38.4V nominal, 7.68kWh) with an industrial smart BMS - supporting CAN 2.0B and RS485 for real-time SOC/SOH, temperature, current and fault telemetry to the vehicle controller or energy-management system. With 100A continuous / 300A peak output in an IP67 sealed enclosure, it is engineered for integrators who need a high-power, observable 38.4V core rather than a sealed consumer pack.

✓ 12S LFP  ✓ 7.68kWh  ✓ 100A Cont.  ✓ CAN/RS485  ✓ IP67
✓ 4000+ Cycles

 

Chemistry LiFePO4 (LFP), 12S architecture
Nominal Voltage 38.4V (3.2V/cell)
Capacity 200Ah
Energy 7.68kWh
Charge Voltage 43.8V cut-off
Discharge Cut-off 30.0V
Continuous Discharge 100A
Peak Discharge 300A (short duration, configurable)
Standard Charge 40A (max 100A fast-charge capable)
BMS Smart BMS: OVP/OCP/SCP/OTP + active/passive balancing; CAN 2.0B + RS485
Communication CAN bus + RS485, register map / DBC provided
Cycle Life >4,000 cycles @ specified DoD
Ingress Protection IP67 sealed enclosure
Dimensions 812.8 × 330.2 × 254 mm
Weight 66 ± 3 kg
Operating Temp. Charge 0–45℃ / Discharge -20–60℃
Compliance UN38.3 / MSDS baseline; CE/UL/IEC docs per project
Warranty 12 months against manufacturing defects (project terms negotiable)

 

Why Smart-Communication Matters for Industrial OEM

CAN + RS485 Dual Link

Talks to motor controller, charger and EMS; no black-box battery.

Live Telemetry

SOC/SOH, cell voltage, temperature and fault codes for fleet or site monitoring.

 

12S Topology

Stable 38.4V bus, matches 36V-class industrial drivetrains.

100A Continuous

Sustains material-handling loads, hill starts and off-grid inverters.

 

BMS & Protection

 

Protection Layers Over-charge / over-discharge / over-current / short-circuit / over-temp / low-temp / cell balancing
Balancing Passive by default; active balancing optional
Communication CAN 2.0B (250kbps) + RS485, register map provided
Pre-charge / Contactor Configurable for high-power drivetrain integration
Self-diagnosis Fault logging, removable terminal, insulated busbar

 

 

Target Applications

🏗️
Material Handling & Tugger Carts

🔋
Industrial Traction & Pallet Trucks

📡
Telecom & Base-Station Backup

🏝️
Off-Grid & Hybrid Microgrid

🧹
Commercial Cleaning Equipment

🏭
Machinery & Mobile Work Platforms

Cell-to-Pack QC
 
 

Why RYDBATT

✅ 20+ Years lithium system integration since 2005.
✅ In-House BMS - CAN/RS485 stack and industrial telemetry developed internally.
✅ Cell-to-Pack QC - grading, formation, aging, full inspection.
✅ Project Scale - samples to volume production for OEM integrators.
✅ Export Ready - documentation for global air/sea freight.
✅ Confidential - NDA before schematic/BMS register exchange.

 

 
 
Quality & Validation
01.

Cell Level 

Capacity, IR and voltage grading before assembly.

02.

BMS Test 

Communication, balancing, protection and recovery verification.

03.

Pack Aging 

Full charge-discharge cycle under load simulation.

04.

Environment

 IP67 sealing, vibration, thermal cycling per batch.

Procurement Info

MOQ Project-based; samples available for validation
Lead Time 20 days for samples; 30–40 days for volume (confirm by qty)
Payment 30% T/T deposit + 70% before shipment
Shipping FOB / CIF / DDP / DDU available
Packaging Custom carton, SOC 30–50%, anti-short-circuit terminals

 

 
FAQ

Q: Is this the same as the existing 38.4V 200Ah golf-cart pages?

A: Electrical core is shared, but those pages target end-user golf carts and range. This page is the industrial OEM module page - focusing on 12S architecture, communication BMS and equipment integration. Old generic pages should 301-redirect or canonical here.

Q: Which communication protocol do I need?

A: Default is CAN 2.0B + RS485. We provide the register map and CAN DBC/signal list so your controller, charger or EMS can read SOC, current, temperature and fault codes.

Q: Can it replace a lead-acid 36V system?

A: Yes. 38.4V LFP sits in the 36V-class window. Use a LiFePO4-compatible CC/CV charger - not a lead-acid charger.

Q: What fast-charge current is supported?

A: Standard 40A, up to 100A with thermal management. Active cooling options available for higher C-rate charging.

Q: Can modules be paralleled?

A: Yes, with managed bus architecture. We provide the parallel/series configuration guide per project.

Q: What certifications are provided?

A: UN38.3 and MSDS baseline. CE/UL/IEC documentation prepared per project and target market.

Hot Tags: 12s 38.4v 200ah lifepo4 module can rs485, golf cart battery, 12s 38.4v 200ah lifepo4 module can rs485 manufacturer, 12s 38.4v 200ah lifepo4 module can rs485 supplier, OEM battery, RYDBATT, 3 7 lithium battery, 9v lithium ion battery, flat pack lithium ion battery, li ion polymer rechargeable battery pack 7 4 v, lithium atv battery, lithium ion battery for e rickshaw